Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
The Journal of Korean Academy of Prosthodontics ; : 106-111, 2012.
Article in Korean | WPRIM | ID: wpr-229222

ABSTRACT

PURPOSE: The purpose of this study was to compare the effect of 3 chairside polishing methods and laboratory polishing methods on surface roughness and C. albicans adhesion of polyamide denture base. MATERIALS AND METHODS: Using contact profilometer, the surface of polyamide specimens (25x15x2 mm) was studied after conventional polishing without finishing and after chiarside polishing with 2 chiarside polishing kits and chairside-pumice polishing following finishing with tungsten carbide bur. To evaluate the adhesion of C. albicans, C. albicans suspension was overlayed on the test specimen. And the specimens were incubated for 2 hours. Imprint culture method was achieved and counted the colony on the agar plate. Polished polyamide were evaluated using a scanning electron microscope. The statistics were conducted using one-way ANOVA and in case of difference, Scheffe test and Tamhane's T2 test were used. RESULTS: Surface roughness (Ra) of surfaces polished with 2 chairside polishing kits had higher than conventional polishing and pumice polishing. The highest roughness value was 0.32 +/- 0.10 microm, and the lowest was 0.02 +/- 0.00 microm. The adhesion of C. albicans on the specimens polished with chairside polishing group and pumice polishing group were increased than conventional polishing group (P.01).


Subject(s)
Agar , Candida , Candida albicans , Denture Bases , Dentures , Electrons , Nylons , Silicates , Tungsten , Tungsten Compounds
2.
The Journal of Korean Academy of Prosthodontics ; : 65-72, 2011.
Article in Korean | WPRIM | ID: wpr-94354

ABSTRACT

PURPOSE: The purpose of this study was to evaluate the level of electro-chemical corrosion and surface roughness change for the cases of Ti abutment connected to restoration made of base metal alloys. MATERIALS AND METHODS: It was hypothesized that Ni-Cr alloys in different compositions possess different corrosion resistances, and thus the specimens (13x13x1.5 mm) in this study were fabricated with 3 different types of metal alloys, commonly used for metal ceramic restorations. The electrochemical characteristics were evaluated with potentiostat (Parstat 2273A) and the level of surface roughness change was observed with surface roughness tester. Paired t-test was used to compare mean average surface roughness (Ra) changes of each specimen group. RESULTS: All specimens made of nickel-chromium based alloys, average surface roughness was increased significantly (P < .05). Among them, the Ni-Cr-Be alloy (0.016 +/- 0.007 microm) had the largest change of roughness followed by Ni-Cr (0.012 +/- 0.003 microm) and Ni-Cr-Ti (0.012 +/- 0.002 microm) alloy. There was no significant changes in surface roughness between each metal alloys after corrosion. CONCLUSION: In the case of galvanic couples of Ti in contact with all specimens made of nickel-chromium based alloys, average surface roughness was increased.


Subject(s)
Alloys , Chromium Alloys , Corrosion , Family Characteristics , Metal Ceramic Alloys , Titanium
SELECTION OF CITATIONS
SEARCH DETAIL